As we all know, under the wide application of balloon catheters today, its own ability and subsequent catheter effect have better quality, and the corresponding structure and characteristic components have a profound impact on the effect of surgery, and the specification of balloon catheters through after-sales service can effectively use this structure to achieve better surgical ability. Customers also need to comprehensively analyze the basic components of this balloon catheter before application, and the following is a simple analysis of the core components of this balloon catheter.
First, the design of its own top
It goes without saying that the outer diameter hardness and length of the tip of the catheter can affect the ability of the balloon to pass through the lesion, and the tapered top design in the structure is conducive to reducing the outer diameter of the tip of the balloon and improving the traceability of the catheter, and the application of laser welding and other technologies is conducive to further reducing the outer diameter of the top of the balloon catheter. In general, short, hard-tipped balloon catheters are more likely to pass through severely narrowed lesions, while long, soft-tipped balloon catheters are more suitable for the management of tortuous lesions.
2. Connection segment
As we all know, as a contact balloon and the push rod between the migration area largely determines the push and flexural ability of the balloon, most of the current capsule connection section is added with a center wire to enhance the support, so that the balloon has better push and flexural ability to achieve safe use.
3. Push rod
It is well known that the use of metal push rod balloon catheter has good pushability, so that the device needs to be sent into the balloon catheter at the same time to treat the lesion, such as bifurcation lesions, the relationship between the outer diameter of the balloon push rod and the inner diameter of the guide tube should also be considered, and a reliable guide tube should be used routinely to improve the success rate of surgery.
From the above, it can be found that the structure design and unique function of this balloon catheter maintain reliable application results. The application of honest and reliable balloon catheter itself is also closely related to the success rate of surgery, so customers need to choose the corresponding device according to their own disease needs, and use the difference between devices to create better surgical utilization results, based on the unique basic structure of this balloon catheter to maintain a better technical way.